B&R±´¼ÓÀ³ËÅ·þÇý¶¯Æ÷άÐÞ±¨¾¯´úÂë7211/7212£¿
7211: DC Á¬½Óµç·£ºµçѹ¶ÏÏß¼ì²é¶¯Á¦ÏßDC link circuit: Voltage breakdown (check the power line)
Info(REAL): Low voltage limit
7212: DC Á¬½Óµç·£ºµçѹ¶ÏÏß¼±Í£ÖжÏ
DC link circuit: Voltage breakdown -> Emergency-Stop interrupted
Info(REAL): Low voltage limit
7213: DC Á¬½Óµç·£ºÊ±¼ä³£Êý¾ö¶¨¼¤»î¶¯Á¦Ïß
DC link circuit: Time constant determination with activ power line
Info(REAL): DC link voltage
7214: DC Á¬½Óµç·£ºµç×è¹ýÈÈ£¨Ì«¶à¶¯Á¦Ïßʧ°Ü£©
DC link circuit: Inrush resistor hot (To much power line fails)
ËÅ·þ½ø¸øÏµÍ³²úÉúÕñ¶¯¡¢ÅÀÐеÄÔÒòÖ÷ÒªÓÐÒÔϼ¸ÖÖ£º
1)»úе²¿·Ö°²×°¡¢µ÷Õû²»Á¼¡£
2)ËÅ·þµç¶¯»ú»òËÙ¶È¡¢Î»Öüì²â²¿¼þ²»Á¼¡£
3)Çý¶¯Æ÷µÄÉ趨ºÍµ÷Õû²»µ±¡£
4)Íⲿ¸ÉÈÅ¡¢½ÓµØ¡¢ÆÁ±Î²»Á¼£¬µÈµÈ¡£
ΪÁË·ÖÇå¹ÊÕϲ¿Î»£¬¿¼Âǵ½»ú´²ËÅ·þϵͳΪ°ë±Õ»·½á¹¹£¬ÍÑ¿ªµç¶¯»úÓëË¿¸ÜµÄÁ¬½ÓºóÔٴ請úÊÔÑ飬·¢ÏÖ¹ÊÕÏÈÔÈ»´æÔÚ£¬Òò´Ë³õ²½Åж¨¹ÊÕÏÔÒòÔÚËÅ·þÇý¶¯ÏµÍ³µÄµçÆø²¿·Ö¡£
ΪÁ˽øÒ»²½Åбð¹ÊÕÏÔÒò£¬Î¬ÐÞʱ¸ü»»ÁËX¡¢YÖáµÄËÅ·þµç¶¯»ú£¬½øÐÐÊÔÑ飬½á¹û·¢ÏÖ¹ÊÕÏ×ªÒÆµ½ÁËYÖᣬÓÉ´ËÅж¨¹ÊÕÏÔÒòÊÇÓÉÓÚXÖáµç¶¯»ú²»Á¼ÒýÆðµÄ¡£
ÉϺ£j9¹ú¼ÊÕ¾±¸ÓÃÍøÖ·µç×ӿƼ¼ÓÐÏÞ¹«Ë¾×¨Òµ´Óʸ÷ÖªÃûÆ·ÅÆËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ,´¥ÃþÆÁάÐÞ,±äƵÆ÷άÐÞ,ËÅ·þÆ÷άÐÞ,ËÅ·þ¿ØÖÆÆ÷άÐÞ,Êý¿ØÏµÍ³Î¬ÐÞ¸ÄÔ죬»úÆ÷ÈËάÐÞ±£ÑøÒÔ¼°¸÷Öְ忨,оƬ¼¶Î¬ÐÞά»¤µÄ¿Æ¼¼ÐÍÆóÒµ,Ãâ·Ñ¼ì²â,¿ìËÙάÐÞ,²¿·ÖÁ¢µÈ¿ÉÈ¡!¹ØÓÚ±´¼ÓÀ³ËÅ·þÇý¶¯Æ÷¹ÊÕϱ¨¾¯Î¬Ð޵Ĵ¦Àí·½·¨£¬¿ÉÒÔ×ÉѯÉϺ£j9¹ú¼ÊÕ¾±¸ÓÃÍøÖ·µç×ӿƼ¼ÓÐÏÞ¹«Ë¾13817011982